Radiol. bras ; 48(1): 21-25, Jan-Feb/2015. tab, graf
Article in English | LILACS | ID: lil-741704

ABSTRACT

Objective: To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods: Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results: In none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion: In the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed. .


Objetivo: Avaliar o nível de radiação no ambiente de um serviço de PET/CT. Materiais e Métodos: Para a determinação dos níveis de radiação no ambiente foram utilizados dosímetros termoluminescentes TLD-100H previamente selecionados e calibrados. Estes detectores foram expostos durante 32 dias em diversos pontos estrategicamente escolhidos nas dependências do serviço e nos prédios adjacentes. Após o período de exposição, os dosímetros foram recolhidos e processados. Resultados: Em nenhum dos pontos avaliados os valores medidos ultrapassaram os limites de restrição de dose para área controlada (5 mSv/ano) ou para área livre (0,5 mSv/ano) recomendados pelas normas brasileiras. Conclusão: Com este trabalho foi possível demonstrar que todas as blindagens do serviço estão adequadas e que, consequentemente, os trabalhadores, desde que seguindo as normas de radioproteção, receberão doses abaixo da dose de restrição indicada no Brasil. .

2.
Radiol. bras ; 47(6): 350-354, Nov-Dec/2014. tab, graf
Article in English, Portuguese | LILACS-Express | LILACS | ID: lil-732743

ABSTRACT

Objetivo: O objetivo deste trabalho é avaliar a dose em pacientes submetidos a PET/CT para diagnóstico de comprometimento cognitivo leve. Materiais e Métodos: Para as medidas da dose absorvida proveniente da modalidade CT utilizaram-se detectores TLD-100 inseridos em um simulador Alderson Rando®. Os simuladores antropomórficos (versões masculina e feminina) foram submetidos aos mesmos protocolos técnicos para aquisição das imagens dos pacientes. A dose absorvida resultante da injeção do radiofármaco foi estimada por meio do modelo proposto pela ICRP 106. Resultados: A dose efetiva a que foram submetidos os pacientes com esta técnica diagnóstica foi, aproximadamente, (5,34 ± 1,99) mSv. Conclusão: Protocolos otimizados para cálculo de atividade radioativa que será injetada em cada paciente podem contribuir para a redução da dose efetiva nos pacientes durante a realização do diagnóstico de comprometimento cognitivo leve com PET/CT. .


Objective: The present study was aimed at evaluating the effective radiation dose in patients submitted to PET/CT for the diagnosis of mild cognitive impairment. Materials and Methods: TLD-100 detectors inserted into an Alderson Rando® anthropomorphic phantom were utilized to measure the absorbed dose coming from the CT imaging modality. The anthropomorphic phantoms (male and female adult versions) were submitted to the same technical protocols for patients’ images acquisition. The absorbed dose resulting from the radiopharmaceutical injection was estimated by means of the model proposed by the ICRP publication 106. Results: The effective dose in patients submitted to this diagnostic technique was approximately (5.34 ± 1.99) mSv. Conclusion: Optimized protocols for calculation of radioactive activity injected into patients submitted to this diagnostic technique might contribute to reduce the effective radiation dose resulting from PET/CT in the diagnosis of mild cognitive impairment. .

3.
Radiol. bras ; 47(5): 288-291, Sep-Oct/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-726338

ABSTRACT

Objetivo: Visando contribuir para o conhecimento das doses em tomografia computadorizada (TC), este trabalho teve o objetivo de quantificar grandezas dosimétricas associadas a exames do abdome em pacientes pediátricos, comparando-as com os níveis de referência em radiodiagnóstico (NRD). Materiais e métodos: O estudo foi realizado em dois hospitais, em um tomógrafo Toshiba Asteion single-slice e um GE BrightSpeed multi-slice. Medidas foram feitas com uma câmara de ionização tipo lápis e um objeto simulador de tronco de polimetilmetacrilato de 16 cm de diâmetro. Resultados: Os valores do índice ponderado de kerma no ar (CW) não apresentaram diferenças significativas, porém, para as grandezas índice de kerma no ar volumétrico (CVOL), produto kerma-comprimento (PKL,CT) e dose efetiva, as diferenças foram relevantes. Conclusão: Apenas o CW apresentou valores menores que os NRD, sugerindo que a otimização não seria necessária. Porém, os valores de PKL,CT e dose efetiva mostraram que há espaço para reduzir as doses de radiação pediátricas. Este trabalho ressalta a importância de avaliar todas as grandezas dosimétricas associadas aos exames por TC. .


Objective: Aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods: The study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results: No significant difference was observed in the values for weighted air kerma index (CW), but the differences were relevant in values for volumetric air kerma index (CVOL), air kerma-length product (PKL,CT) and effective dose. Conclusion: Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, PKL,CT and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. .

4.
Radiol. bras ; 46(5): 284-289, Sep-Oct/2013. tab, graf
Article in English | LILACS | ID: lil-690164

ABSTRACT

Objective To suggest a national value for the diagnostic reference level (DRL) in terms of activity in MBq.kg–1, for nuclear medicine procedures with fluorodeoxyglucose (18F-FDG) in whole body positron emission tomography (PET) scans of adult patients. Materials and Methods A survey on values of 18F-FDG activity administered in Brazilian clinics was undertaken by means of a questionnaire including questions about number and manufacturer of the installed equipment, model and detector type. The suggested DRL value was based on the calculation of the third quartile of the activity values distribution reported by the clinics. Results Among the surveyed Brazilian clinics, 58% responded completely or partially the questionnaire; and the results demonstrated variation of up to 100% in the reported radiopharmaceutical activity. The suggested DRL for 18F-FDG/PET activity was 5.54 MBq.kg–1 (0.149 mCi.kg–1). Conclusion The present study has demonstrated the lack of standardization in administered radiopharmaceutical activities for PET procedures in Brazil, corroborating the necessity of an official DRL value to be adopted in the country. The suggested DLR value demonstrates that there is room for optimization of the procedures and 18F-FDG/PET activities administered in Brazilian clinics to reduce the doses delivered to patients. It is important to highlight that this value should be continually revised and optimized at least every five years. .

5.
Radiol. bras ; 46(2): 96-100, mar.-abr. 2013. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-673352

ABSTRACT

OBJETIVO: Verificar a viabilidade de filmes radiocrômicos como um dosímetro alternativo para estimativa da dose média em cortes múltiplos a partir dos perfis de kerma.MATERIAIS E MÉTODOS: Os filmes foram distribuídos em cilindros posicionados no centro e nas regiões periféricas de um objeto simulador padrão de abdome utilizado para dosimetria em tomografia computadorizada.RESULTADOS: Os valores de dose média em cortes múltiplos calculados foram 13,6 ± 0,7, 13,5 ± 0,7 e 18,7 ± 1,0 mGy para os valores de passo (pitch) de 0,75, 1,00 e 1,50, respectivamente.CONCLUSÃO: Apesar de os resultados mostrarem valores menores que o nível de referência de radiodiagnóstico de 25 mGy estabelecido pela legislação brasileira para exames de abdome, eles sugerem que há espaço para otimização dos procedimentos e uma revisão do valor para o nível de referência de radiodiagnóstico brasileiro.


OBJECTIVE: To evaluate the feasibility of using radiochromic films as an alternative dosimeter to estimate the multiple scan average dose on the basis on kerma profiles.MATERIALS AND METHODS: The radiochromic films were distributed in cylinders positioned in the center and in four peripheral bores of a standard abdominal phantom utilized for computed tomography dosimetry.RESULTS: Values for multiple scan average dose values corresponded to 13.6 ± 0.7, 13.5 ± 0.7 and 18.7 ± 1.0 mGy for pitch of 0.75, 1.00 and 1.50, respectively.CONCLUSION: In spite of results showing lower values than the reference level for radiodiagnosis (25 mGy) established by the Brazilian regulations for abdominal studies, it is suggested that there is room to optimize procedures and review the reference level for radiodiagnosis in Brazil.


Subject(s)
Humans , Male , Female , Dosimetry/methods , Kerma , Government Agencies , Guidelines as Topic , Tomography, X-Ray Computed/standards
6.
Radiol. bras ; 41(5): 325-329, set.-out. 2008. graf, tab
Article in English, Portuguese | LILACS | ID: lil-496937

ABSTRACT

OBJETIVO: Os objetivos deste trabalho são: a) avaliar os procedimentos radiográficos e estimar o valor do kerma no ar na superfície de entrada nos recém-nascidos prematuros submetidos a exames de tórax e abdome, realizados no setor de neonatologia de um hospital público de Belo Horizonte; b) estimar as doses nos órgãos e os respectivos riscos de ocorrência de câncer nesses órgãos em decorrência das exposições à radiação. MATERIAIS E MÉTODOS: Foram analisados os prontuários dos pacientes internados no setor de neonatologia desse hospital durante o período de maio a setembro de 2004, anotando-se os dados antropométricos, data de internação/alta, exames de raios X realizados. O kerma no ar na superfície de entrada foi determinado a partir do rendimento do tubo de raios X e dos parâmetros de irradiação utilizados nos exames. As doses nos órgãos foram estimadas com o software PCXMC e o risco, durante o restante da expectativa de vida, com o software IREP. RESULTADOS: O valor médio do kerma no ar na superfície de entrada por exame foi abaixo do nível de referência da publicação da Comunidade Européia. Para o paciente mais severamente irradiado, os órgãos mais suscetíveis à ocorrência de câncer foram fígado, mama e estômago, com valores máximos de excess relative risk, respectivamente, de 3,4 por cento, 2,3 por cento e 1,7 por cento. CONCLUSÃO: Foi constatada a necessidade de otimização dos procedimentos radiográficos com vista à diminuição do risco para os recém-nascidos, que apesar de ser considerado baixo (comparativamente ao benefício), deve ser sempre diminuído para valores tão baixos quanto razoavelmente exeqüíveis.


OBJECTIVE: The present study was aimed at: a) evaluating radiographic procedures and estimating entrance surface air kerma in preterm neonates submitted to chest and abdominal radiography at the unit of neonatology in a public hospital of Belo Horizonte, MG, Brazil; b) estimating the dose to organs and respective risks for cancer as a result from radiation exposure. MATERIALS AND METHODS: Records of patients admitted to the unit of neonatology of this hospital in the period between May and September 2004 were reviewed. Anthropometric data, admission/discharge dates and radiographic studies performed were recorded for each of the patients. The calculation of the entrance surface air kerma was based on the x-ray tube output and irradiation parameters adopted for examinations. Dose to organs was calculated with the aid of the software PCXMC, and the lifetime risk for cancer, with the software IREP. RESULTS: Mean entrance surface air kerma per examination was below the diagnostic reference levels recommended by the European Community. In the most severely irradiated patients, liver, breast and stomach were the organs at highest risk for cancer, with maximum excess relative risk of respectively 3.4 percent, 2.3 percent, and 1.7 percent. CONCLUSION: The present study demonstrated the need for optimization of radiographic procedures in order to reduce the risks for neonates that, in spite of being considered to be low as compared with the benefits, should be reduced to values as low as reasonably achievable.


Subject(s)
Humans , Male , Female , Infant, Newborn , Dosimetry/adverse effects , Kerma , Neoplasms, Radiation-Induced , Radiation Protection , Radiation Risks , Carcinogens , Radiation, Ionizing , Radiometry , Risk Assessment
7.
Radiol. bras ; 40(6): 409-413, nov.-dez. 2007. graf, tab
Article in English, Portuguese | LILACS | ID: lil-472001

ABSTRACT

OBJETIVO: Avaliar a freqüência das incidências radiográficas realizadas nos seios da face de pacientes pediátricos em hospitais de Belo Horizonte, MG, as condições de radioproteção, as técnicas radiográficas empregadas, o kerma no ar de entrada e as doses nos órgãos mais expostos. MATERIAIS E MÉTODOS: Foram coletados os dados dos pacientes e parâmetros de técnica radiográfica empregados em exames de crianças de 1 a 16 anos de idade, em cinco salas de quatro hospitais da cidade, observando, também, aspectos de proteção radiológica. O kerma no ar de entrada foi estimado a partir dos rendimentos dos tubos de raios-x e as doses nos órgãos utilizando o software PCXMC. RESULTADOS: Os valores médios do kerma no ar de entrada para as cinco salas foram, respectivamente, 1.398 µGy, 829 µGy, 877 µGy, 1.168 µGy e 3.886 µGy para pacientes entre 1 e 5 anos de idade. CONCLUSÃO: Foi constatado que as incidências mento-naso e fronto-naso são comumente solicitadas em conjunto, na maioria dos hospitais, o que confere dose significativa para os pacientes. Os riscos para os pacientes podem ser diminuídos mediante a utilização de cilindros de colimação, a não-utilização de grades antiespalhamento, o emprego de altos valores de tensão e baixos valores de tempo.


OBJECTIVE: The present study was aimed at evaluating the frequency of radiographic assessment of paranasal sinuses in pediatric patients in hospitals of Belo Horizonte, MG, Brazil. Additionally, aspects regarding radiation protection conditions and radiographic parameters were evaluated, and entrance air kerma and organ doses were estimated. MATERIALS AND METHODS: Patients' data and parameters of radiographic technique employed in the assessment of children in the age range between 1 and 16 years were collected in five examination rooms of four hospitals in Belo Horizonte, also taking into consideration the radiation protection aspects. Entrance air kerma calculation was based on the x-ray tubes output, and organ doses were estimated with the PCXMC software. RESULTS: Mean entrance air kerma values found in the five rooms were, respectively, 1398 µGy, 829 µGy, 877 µGy, 1168 µGy and 3886 µGy for patients with ages between 1 and 5 years. CONCLUSION: Most frequently, mento-naso and fronto-naso views are requested in conjunction in the majority of hospitals, which increases the radiation dose to the patients. It may be concluded that the risks for patients can be reduced by means of the utilization of an appropriate x-ray field, non-utilization of antiscattering grids, selection of high voltages and lower exposure times.


Subject(s)
Humans , Male , Female , Infant , Child, Preschool , Child , Adolescent , Radiation Exposure , Radiation, Ionizing , Dose-Response Relationship, Radiation , Sinusitis , Radiation Dosage , Kerma
8.
Radiol. bras ; 40(5): 331-336, set.-out. 2007. graf, tab
Article in English, Portuguese | LILACS | ID: lil-467769

ABSTRACT

OBJETIVO: A análise crítica da metodologia de medida da camada semi-redutora em feixes de raios X teve como base o regulamento técnico para proteção radiológica e controle de qualidade em radiodiagnóstico médico e odontológico. MATERIAIS E MÉTODOS: Na medida da camada semi-redutora, a técnica radiográfica, o arranjo experimental, os meios espalhadores, a instrumentação, o tamanho de campo de radiação e a metodologia de análise dos dados foram considerados. RESULTADOS: A camada semi-redutora obtida em condições de boa geometria, para a técnica escolhida, foi de 2,44 ± 0,02 mmAl. Em relação a este valor, observaram-se desvios máximos na camada semi-redutora de 4,1 por cento na variação da geometria, de 98,8 por cento na variação da câmara de ionização e do meio espalhador, e de até 29,5 por cento com outro tipo de detector. CONCLUSÃO: Os resultados mostraram que não ocorre variação significante na camada semi-redutora para diferentes tamanhos de campo de radiação, mas foram evidentes a influência do espalhamento na superestimação da camada semi-redutora e a redução desta na presença de blocos de chumbo como meio espalhador. O procedimento prático adotado mostrou-se bastante confiável e evidenciou a grande discrepância decorrente da adoção de metodologias impróprias, enfatizando a necessidade de estabelecer um procedimento padrão para a medida da camada semi-redutora.


OBJECTIVE: The critical analysis of the methodology for evaluating the x-ray beam half-value layer was based on technical standards for radiological protection and quality control in medical and dental diagnoses. MATERIALS AND METHODS: Exposure parameters, experimental set-up, scattering materials, instrumentation, size of radiation field and methodology of data analysis have been taken into consideration for measurements of half-value layer. RESULTS: The half-value layer, in good geometry, measured 2.44 ± 0.02 mmAl. A maximum deviation of 4.1 percent was found under other geometry conditions. A 98.8 percent deviation was observed with a different ionization chamber, and scattering material, and 29.5 percent with another type of detector. CONCLUSION: Results showed that no relevant variation is observed in the half-value layer for different radiation field sizes. On the other hand, the influence of the radiation scattering on the half-value layer overestimation was clearly observed, as well as the half-value layer reduction in the presence of lead used as scattering material. The practical methodology adopted for half-value layer evaluation has shown to be quite reliable, besides evidencing remarkable discrepancies resulting from the adoption of inappropriate methodologies, emphasizing the necessity of establishing a standard procedure for measuring the half-value layer.


Subject(s)
Radiation Protection/methods , Radiology/instrumentation , Radiology/standards , Radiometry/methods , Technology, Radiologic , Radiation Dosage , Quality Control , Radiation Protection